Last Updated on  10.01.2022

SAFETY ACTION PLAN FOR 2021-22

S.No.

Item

Unit

Target for
2021-22

Prop Target Dec'2021

Progress Till Dec'2021

1

Accident on S&T account

 

 

 

 

 

(a) No. of accidents due to Equipment failure

Nos

0

0

0

 

(b) No. of accidents due to Human failure

Nos

0

0

0

2

Failure of equipment on unsafe side

Nos

0

0

0

3

Safety Inspection by S&T officials

 

 

 

 

(a) Safety inspection at  Sectional Inspector level (Monthly)

Nos

588

441

440

 

(b) Safety inspection at  Incharge Inspector level(Quarterly).

Nos

196

146

146

 

(c)Safety inspection at  ASTE, DSTE, Sr.DSTE’s level (Yearly)

Nos

47

35

176

4

Joint Inspection of S&T officials

 

 

 

 

(a) Foot plate inspection by CSI/CL.I & CDTI (Quarterly)

Nos

32

24

54

 

(b) Points & Crossings by CSI/PWI

Nos

174

131

132

5

Training of safety category staff (Refresher)

 

 

 

 

(a) Signal Supervisors ( Once in 5 years )

Nos

7

5

4

 

(b) Telecom. Supervisors ( Once in 5 years )

Nos

1

1

1

 

(c) Signal Maintainers ( Once in 5 years ) 

Nos

50

38

30

 

(d) Telecom. Maintainers ( Once in 5 years )

Nos

10

8

10

 

(e) Safety Seminar (2 Nos.per month.Divn.)

Nos

24

18

18

6

Periodical Medical examination of safety category staff

Nos

20

15

22

7

Overhauling of Signalling equipment

 

 

 

 

a) Lever frame ( Once in 3 years )

Nos

2

2

2

 

b) Block instrument (DLBI-once in 7yrs & SLBI/TLBI-once in 10 years)

Nos

4

3

4

 

c) Cable meggering

Nos

0

0

0

S.No.

Item

Unit

Target for
2020-21

Prop Target Dec'2021

Progress Till Dec'2021

8

Sign off Register - Compliance of defficiencies reported

Nos

0  

0

0

9

Joint checking of emergency sockets (Quarterly by SE/Tele & SSE/OHE)

Nos

1000

750

1373

10

Inspection of ART & ARME equipments

 

 

 

 

(a) Inspection at JE/SSE level (Monthly).

Nos

15

11

12

 

(b) Inspection at Officer level (Quarterly)

Nos

4

3

4

11

Inspection & testing of assets for Disaster Management

 

 

 

 

(a) Inspection at JE/SSE level (Monthly).

Nos

15

11

12

 

(b) Inspection at Officer level (Quarterly)

Nos

4

3

4

12

Provision of shortfall safety materials in ART/ARME.

 

a

Provision of one more satellite phone at all ARTs

Nos

All ready
 provided

--

--

b

Provision of System showing the coverage availability of measure mobile service provider in ART

Nos

All ready
 provided

--

--


Cause Wise Signal incidences (As per ICMS) for the asset failures pertaining to S&T during 2020-21 & 2021-22

Code

Cause

APR’20

APR’21

MAY'20

MAY'21

JUN'20

JUNE'21

JUL'20

JULY'21

AUG'20

AUG'21

SEPT'20

SEPT'21

OCT'20

OCT'21

NOV'20

NOV'21

DEC'20

DEC'21

JAN'21

JAN'22

FEB'21

FEB'22

MAR'21

MAR'22

2020-21

2021-22

1.1.a

Signal Lamp Fusing

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.1.b.1

LED Lamp fuse

0

2

0

0

0

2

1

0

3

3

0

3

1

1

0

0

1

1

 

 

 

 

 

 

6

12

1.1.b.2

CR/HMU of LED lamp defective

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.1.c

Tripple Pole Lamp Fuse

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.1.d

Signal Transormer

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.10.a

Locking Jam

0

0

0

0

0

0

0

0

0

0

0

0

1

0

1

0

0

0

 

 

 

 

 

 

2

0

1.10.b

Lever Frame

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.10.c

SM Slide

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.11

Mechanical Transmission Defects

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.12.a

Rodding Compensators/Crank Defects

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

 

 

 

 

 

 

1

0

1.12.b

Mechanical Detector

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.12.c

FPL/LB

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

 

 

 

 

 

 

1

0

1.12.d

EPD

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.13.a

Bad Maintenance

0

0

0

1

0

0

0

0

1

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

1

1

1.13.b

Point Adjusted

2

5

1

0

1

3

2

4

4

4

2

3

1

1

2

1

6

0

 

 

 

 

 

 

21

21

1.13.c

Jamming

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.13.d

Breakage of Part

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.a1

Analog Axle Counter Failure

1

0

0

0

1

0

0

0

0

0

0

0

1

0

0

0

1

0

 

 

 

 

 

 

4

0

1.14.a2

EJB of Universal Axle Counter

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.b1

Digital Axle Counter Failure

1

0

0

0

1

1

0

0

0

1

0

1

0

0

0

0

1

0

 

 

 

 

 

 

3

3

1.14.b2

Track Device of SSDAC/MSDAC/UAC

2

0

0

0

0

1

1

0

0

0

0

0

1

0

0

0

1

0

 

 

 

 

 

 

5

1

1.14.b3

Reset/UAC/SSDAC/MSDAC

1

1

1

4

1

6

0

2

0

1

1

6

3

1

0

2

0

0

 

 

 

 

 

 

7

23

1.14.c1

Track Circuit Failure

0

2

0

1

0

0

1

0

0

0

2

2

0

0

0

0

0

0

 

 

 

 

 

 

3

5

1.14.c2

Track Feed Resistance

0

0

0

0

0

0

0

0

1

0

0

0

0

0

1

0

0

0

 

 

 

 

 

 

2

0

1.14.c3

Track Battery Charger

0

0

0

0

2

0

0

0

1

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

3

0

1.14.d

S&T Disconnection

2

0

0

0

0

0

0

0

1

1

2

0

0

0

0

0

0

1

 

 

 

 

 

 

5

2

1.14.e

Earth Fault

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.f

'E' type Lock failure

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.g1

LC Gate Failure (Mech)

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

 

 

 

 

 

 

1

0

1.14.g2

Electric Lifting Barrier

0

1

0

2

0

0

1

3

0

1

0

1

1

0

2

0

1

1

 

 

 

 

 

 

5

9

1.14.h

SSI Equipment Failure

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.i

EKT/HKT Failure

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

0

0

1.14.j

Point Machine Failure

0

1

0

0

1

0

0

0

1

1

1

5

0

0

0

2

1

0

 

 

 

 

 

 

4

9

1.14.k

Communication Failure

0

0

0

0

0

0

0

0

0

1

0

0

0

0

1

0

0

0

 

 

 

 

 

 

1

1

1.14.l

Circuit Kept Under Observation

2

10

6

3

6

5

5

7

7

5

4

7